SCH have an option of automatic viscosity control and top up system for the DS101 dip coating system. Can you advise how this works?

Automated viscosity control is a sophisticated process reserved for companies who are going to process a lot of PCBs and change the viscosity of the tank a lot of times in a shift or for companies who want a totally closed loop process without manual adjustment.

The viscosity system is an inline viscometer with feedback monitoring the tank constantly. There is a dosing system that would adjust the coating as required, feeding back into the conformal coating tank either conformal coating material or conformal coating thinners.

Click Conformal Coating Dipping FAQs to find out more about this and other issues relating to the process.

Advertisements

Tags: , , , , , ,

About Dr Lee Hitchens

Dr Hitchens has been working in the electronics industry and the area of conformal coatings for over 25 years in various areas including sales and technical support. He has also been training people for almost the same amount of time in all areas of conformal coating whether that is materials & equipment selection, process development or troubleshooting to help them solve their particular problem. Recently, he decided that the industry needed a specific place where all of the useful knowledge on conformal coatings could be collated for users to find easily and use in their own production process. So, Nexus was born and he began the Nexus eBook project.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: